OPERATION & MAINTENANCE MANUAL SWE18UF
not possible to predict every circumstance which might
involves potential hazards. So it’s necessary to ask for
instruction from your superior before attempting any
operation or maintenance procedure.
(2) Engine Operation Label
Diesel engine inspection
Stop machine on level ground, inspect engine oil level (stop
engine for longer than 15 minutes to allow engine oil to go
back to the bottom), inspect dipstick to make sure oil level
must be between the lines of “MIN” and “MAX”. For
engine maintenance procedures, please refer to the “diesel
engine maintenance manual” enclosed with the other
literature of the machine.
Pre-start inspection
Keep control lever of pilot valve in LOCK position, pilot
joystick and travel pull link are in normal position (neutral
position), operator sit over seat.
While switching the key to ON position, except engine
hour meter and LCD module, all indicators of test system
must light up. Buzzer must sound as well. Self-test is
finished in 2 seconds to indicate test system is or is not
properly functioning.
Start the engine
Keep control lever of pilot valve at LOCK position.
Switch key to ON position.
Honk the horn to alert the persons around.
Turn the key to the right; hold it in START position until
engine runs. Then release the key, switch will automatically.
Return to ON position.
Caution
Do not operate motor for longer than 5 seconds ever
time to avoid damage to machine. In case of failure
to start engine, switch the key back to OFF position,
wait 2 minutes before a new attempt. Incorrect start
may damage to starter.