OPERATION & MAINTENANCE MANUAL SWE18UF
4
(3) Diesel Label
Caution
Refilling fuel with extra care. Stop engine
before refilling fuel. Do not smoke while refilling
to fuel tank or operating around fuel system.
Select proper fuel according to different ambient
temperature.
Refer to “stop engine” section for properly parking
machine and stopping engine.
Inspect fuel gauge on monitor, top up is required.
Prevent dirt, dust, water and other foreign matter from
entry into oil tank and fuel system.
While refilling at the end of daily work-shift, do not
spill, drip any fuel to machine or ground to avoid fuel
clotting.
After refilling fuel, fasten cap securely.
(4Machine Posture Label
Caution
Do not start engine when hydraulic oil tank
runs out of oil.
Inspect hydraulic oil level……every day
Park machine on level ground.
Completely retract arm cylinder and extend bucket
cylinder to full length.
Lower bucket down to the ground.
Run engine at low speed for 5 minutes.
Shut down engine, remove the key.
Place pilot control lever to LOCK (up) position.
Open right side door to check oil level gauge. Located
Caution
Posture for Checking Hydraulic Oil Level
Caution