Command Line Interface
5-55
COMMAND MODES: Global configuration
R
EFERENCE:
M
ENU:
EXAMPLE:
!set CIST Hello Time 5 seconds
Switch(config)# spanning-tree mst hello-time 5
Switch(config)#
spanning-tree mst forward-time
Use the spanning-tree mst forward time command to configure the CIST bridge Forward Time value.
spanning-tree mst forward-time <seconds>
S
YNTAX DESCRIPTION: <seconds> Integer ranges from 4 to 30 and enforces the following
relationships
2* (Bridge _Forward_Delay - 1.0 seconds) >=Bridge_Max_Age
Bridge_Max_Age>=2* (Bridge_Hello_Time + 1.0 seconds)
From (Bridge_Max_Age / 2) + 1 to 30
D
EFAULT VALUE:
C
OMMAND MODES: Global configuration
R
EFERENCE:
M
ENU:
E
XAMPLE:
! Set Forward Time 12 seconds
Switch(config)# spanning-tree mst forward-time 12
Switch(config)#