CROSS FORMA: Service & Maintenance Manual - rev. 2.1
Page 9.10
9.2.3.4. View Errors
The error history log records the following information for each of the errors generated by the
machine:
Error code
Type of error
Current when the error occurred
Distance in km when the error occurred
A description of each error code is given in the table below:
Error
Code
Description
1
OVERHEATING: this condition occurs when the temperature measured
by the sensor on the circuit board exceeds 90°C.
2
OVERCURRENT: this condition occurs when the current going to the
solenoid measured by the board exceed the max value.
8
OVERVOLTAGE: this condition occurs when the +12 Vdc voltage goes
above 13.7 Vdc.
16
WATCHDOG: this condition occurs when the brake board SW crashes.
Use the + effort level key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.
9.2.4. STANDARD SETTINGS
This function simultaneously resets the brake board parameters to their default values, and clears the
operating data of the machine. To access this menu, when the display shows:
STANDARD SETTINGS ?
press ENTER, the following message appears:
CONFIRM ?
Press ENTER again to reset all parameters to their default values, or return to the upper menu level
by pressing CLEAR for a few seconds.
This function does not alter the language setting.
9.2.5. LOW KIT MENU
This function directly accesses the firmware of the Brake board. To access this menu, when the
display shows:
LOW KIT MENU
press ENTER. This function is structured as follows: