CROSS FORMA: Service & Maintenance Manual - rev. 2.1
Page 6.18
6.9. THERE IS NO HEART RATE SIGNAL
THERE IS NO HR
SI GN AL
(Chest Belt)
Check if the +5Vdc are at the
input of the Receiver Board.
Are them present?
ARM/ CPU Board
defective.
Replace.
3
NO
SI
Check if the +5Vdc are at the
output of the ARM/CPU Board.
Are them present?
4
NO
Receiver Board
defective.
Replace.
Check the SW and the groundin
of Receiver Board.
Problem persists?
Place correclty
1
YES
NO
Check the proper functioning
of the Receiver Board.
Is proper placed?
OK
2
NO
NO
YES
YES
Check if it works properly using
a chest belt you are sure it's ok.
The problem solved?
Chest Belt
defective
SI
Replace the connecting
cable between the High
Kit and the Low Kit.
YES
YES
Continues on the next page...