CROSS FORMA: Service & Maintenance Manual - rev. 2.1
Page 9.7
9.2.1.4. Table of configuration parameters
Display
parameter
Description
Default value
Par 01
Transmission ratio
125
Par 02
Speed ratio
1
Par 03
Minimum braking current (standby position)
0
Par 04
Maximum continuous power
200
Par 05
Machine torque correction coefficient (constant torque)
100
Par 06
User friction torque
30
Par 07
Maximum coil temperature
125
Par 08
Minimum revolutions (RPM)
35
Par 09
RPM integration scale
1
Par 10
Filter threshold (RPM)
75
Par 11
Speed ratio (decimal part)
57
Par 12
User friction torque delta
30
Par 13
-
0
9.2.2. OPERATING DATA
This function makes it possible to access the machine usage data stored in the low kit. To access
this menu, when the display shows:
OPERATING DATA
press ENTER. This function is structured as follows:
OPERATING DATA
Life Kit H
Life Brake
WRITE TO
LOW KIT ?
READ FROM
LOW KIT ?
Life Kit L
Tot. Km
KJ
In addition to the machine usage data, this function also includes the 2 sub-functions described
below: