or source current as outputs, and independently be driven from sinking or
sourcing devices when used as inputs.
You may also note that each I/O circuit is protected by a 48V bi-
directional clamp diode to protect against inductive kickback from
connected coils (relays, contactors, solenoid valves, etc.)
IMPORTANT: The motor cable connectors must be properly tightened
to maintain IP67 (waterproof) rating. Failure to tighten these connectors
may result in motor damage due to water ingress. Tighten until 1-2
threads are visible on the motor's M12 connectors.