POWER4-HUB-S
DC Bus Motor Power (Input from DC Bus Motor Supply)
Nominal voltage range 24VDC to 75VDC
Max. input voltage 100VDC
Max. continuous current 20A
Peak current (3 seconds) 50A
Connectors 2-pin Molex Sabre (P1, P2)
Logic Power (Input from Logic Power Backup Supply)
Nominal voltage range (touch-safe) 12VDC to 42VDC
Max. input voltage 100 VDC
Max. continuous current 10A
Max. peak current 10A
Connectors 2-pin Molex MiniFit Jr. (P3, P4)
DC Bus Motor Power (Output to ClearPath motors)
Max. motors 4
Connectors 4-pin Molex MiniFit Jr. (P1, P2, P3, P4)
Dielectric Withstand Voltage
Between DC Bus and Backup Power 1,600 VDC
Between DC Bus and chassis plate 1,600 VDC
Between Backup Power and chassis plate 1,600 VDC
Environmental
Operating temperature** -40°C to +70°C
Long term storage temperature -40°C to +50°C
Pollution Degree 2
Dimensions
L x W x H (w/o baseplate) 3.37" x 2.23" x 0.67"
L x W x H (with baseplate) 3.62" x 2.35" x 1.03"
Country of Origin USA
Warranty 1 year
**For operation over 40°C refer to power derating data