Saving Waveforms and Setups 
\ 
[ 
SAVE 
REF 
0 
L 
1 
2 
ONIOFF 
3 
4K 
J 
Figure 3-42:  SAVE REF Memory Buttons 
Recalling a Waveform from SAVE REF 
Once a waveform is stored in a 
SAVE REF 
memory location, simply press 
the memory location button to recall or remove it from memory. The con- 
tents will remain intact even after the power is turned off. There is no over- 
write protection on these memories, however. Pressing the 
SAVE REF 
and 
memory location button will save a new waveform to that location and 
overwrite the old. 
Comparing Saved Waveforms 
You can simultaneously display the contents of more than one 
SAVE REF 
memory location. This enables you to compare one saved waveform with 
another. 
Step 
1 
: 
Press one or more memory location buttons to display their 
respective contents. 
Step 2: 
Change the position, horizontal magnification, or vertical gain of 
the saved waveform display using the 
Format 
reference menu. (Refer to 
the following section.) 
Step 3: 
Press the 
SELECT WAVEFORM 
button (next to the cursor 
control) one or more times until the cursors appear on the waveform you 
want to measure. An underscore appears under the selected 
SREF 
memory number at the top of the display. 
Formatting Saved Waveforms 
You can change the horizontal magnification, vertical position, and vertical 
gain of a waveform in a 
SAVE REF 
memory location. 
Step 
1 
: 
Press the front-panel Setup 
REF 
button. 
Step 
2: 
Press the left 
Save Ref 
menu to indicate 
Format. 
The 
Format 
Reference Menu appears (Figure 3-43). 
Step 3: 
Select the 
Target Ref 
(Refl, Ref2, Ref3, or Ref4K) to indicate 
the desired memory location. 
3-46 