Troubleshooting
TDS5000B Series Service Manual
6-- 55
If there is a display on the VGA port, but not on the LCD, replace the display
assembly (LCD, lamps, and cable).
If the display adapter is bad, the BIOS should report it using beep codes (see
Table 6--10, on page 6--62).
If nothing is displayed, is the display turned on? At boot time and while using an
external monitor connected to the PC motherboard external video port, press F2
to enter the BIOS setup. The Advanced Video Configuration menu lets you select
PCI (LCD) or AGP (the PC motherboard port on the upper-side panel). The
lower VGA port on the side panel is the PCI video port (driven by the same
video controller as the LCD).
If the oscilloscope will not boot, press F8 to enter the start up menu, and boot to
the command prompt. If you can boot to the command prompt, use the MSDOS
Edit program to edit the autoexec.bat file to run the CMOS restore utility (see
Update/Restore the PC Motherboard CMOS on page 6--66).
If booting starts, finds the hard disk, but hangs at the Windows splash screen:
1. Select the AGP video port using the setup menu.
2. Disconnect the PC motherboard from the PC Interface board.
3. If the system boots (It will only boot to Windows; the oscilloscope applica-
tion will not run) to the external PC motherboard video port, replace the PC
Interface board.
If the oscilloscope boots into Windows, but the oscilloscope application does not
work (the DPO Man graphic is displayed), check the following:
1. The application software.
2. The Acquisition board.
3. The PC Interface board.
4. Did someone exit the application using the Task Manager and then try to
reenter the application without rebooting?
5. If the relays click, the acquisition is running.
6. Check the desktop properties (right click on the desktop and select Proper-
ties). On the Settings tab, 16 bit is required. Video merge will not work with
other settings. If you change the setting, reboot.
7. On the Settings tab of the desktop properties, select Advanced and then the
Performance tab. Hardware Acceleration must be set to Full for video merge
to work. If you change the setting, reboot.
If the Oscilloscope Will
Not Boot
Booting Into Windows
If the Oscilloscope
Application Does Not
Work

Table of Contents

Other manuals for Tektronix TDS5000B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS5000B Series and is the answer not in the manual?

Tektronix TDS5000B Series Specifications

General IconGeneral
BrandTektronix
ModelTDS5000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals