First steps.............................................................................................. 31
5.1. Commissioning ............................................................................. 31
5.2. Getting to know the analyzer......................................................... 31
5.2.1. Power supply, batteries/rechargeable batteries ............................................. 31
5.2.1.1. Recharging the rech. batt. of the Control unit .................................. 31
5.2.1.2. Charging the rech. batt. of the analyzer box .................................... 32
5.2.1.3. Battery care.....................................................................................32
5.2.1.4. AC Power supply............................................................................. 32
5.2.2. Connecting probes / sensors ......................................................................... 33
5.2.3. Occupying the trigger input ............................................................................ 34
5.2.4. Connecting system components.................................................................... 34
5.2.4.1. Connection using contact strip.........................................................34
5.2.4.2. Connection using a Data bus cable (accessory part to a bus system)35
5.2.4.3. Connection via Bluetooth (option).................................................... 38
5.2.5. Switching on .................................................................................................. 39
5.2.6. Calling up a function ...................................................................................... 40
5.2.7. Entering values..............................................................................................40
5.2.8. Printing / saving data ..................................................................................... 42
5.2.9. Search for meras. boxes................................................................................ 42
5.2.10. Confirming an error message ........................................................................ 42
5.2.11. Switching off .................................................................................................. 43
5.3. Folders / Measurement sites......................................................... 43
5.4. Saved Measurements ................................................................... 46
5.5. Instrument diagnosis..................................................................... 47
5.5.1. Error diagnosis .............................................................................................. 48
5.5.2. Gas path check..............................................................................................48
5.5.3. Sensor diagnosis ...........................................................................................48
5.5.4. Instrument information................................................................................... 48
6 Using the analyzer ................................................................................ 49
6.1. Settings......................................................................................... 49
6.1.1. Assigning the right hand function key ............................................................49
6.1.2. Instrument settings ........................................................................................ 49
6.1.2.1. Dilution ............................................................................................49
6.1.2.2. Measurement view .......................................................................... 51
6.1.2.3. Units................................................................................................53
6.1.2.4. Date / time.......................................................................................54
6.1.2.5. Power options.................................................................................. 54
6.1.2.6. Display brightness ........................................................................... 54
6.1.2.7. Printer ............................................................................................. 55
6.1.2.8. Bluetooth......................................................................................... 55
6.1.2.9. Language ........................................................................................ 56
6.1.2.10. Country version ............................................................................... 56
6.1.2.11. Password protection........................................................................57
6.1.2.12. Analog input .................................................................................... 58
6.1.2.13. Data bus.......................................................................................... 58
w ww . . co m
information@itm.com1.800.561.8187

Table of Contents

Other manuals for TESTO 350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 350 and is the answer not in the manual?

TESTO 350 Specifications

General IconGeneral
Measurement ParametersO2, CO, NO, NO2, SO2, H2S, CO2, CxHy, H2, Temperature, Draft, Pressure
O2 measurement range0 to 25 vol. %
CO measurement range0 to 10, 000 ppm
SO2 measurement range0 to 5, 000 ppm
Resolution H21 ppm
Accuracy O2±0.2 vol. %
DisplayGraphic display
CommunicationUSB, Bluetooth
Power SupplyRechargeable battery
Operating Temperature-5 to 45 °C
Accuracy CO±5 ppm or ±5% of measured value
Accuracy NO±5 ppm or ±5% of measured value
Accuracy NO2±5 ppm or ±5% of measured value
Accuracy SO2±5 ppm or ±5% of measured value
Accuracy H2S±5 ppm or ±5% of measured value
Accuracy H2±5 ppm or ±5% of measured value
Draft measurement range-99.9 to +99.9 hPa