Activating the function:
> Measurement Type Gas flow calc. [OK].
Performing the measurement:
1. Start measurement: [
].
- The measuring duration is displayed.
2. When the adjusted gas flow is reached: [ ].
- The calculated gas flow and the gas burner capacity (in kW) are
displayed.
Options:
> [Options] Print: The readings from a record are printed.
> [Options] Save: The readings are saved in a record.
> [Options] Change Gas amount: Set the gas amount value.
> [Options] Change unit: The unit for the gas flow can be
changed (m3 > l or l > m3).
6.2.3.5. Oil flow calculation
The function is only available if the chosen fuel is an oil.
Activating the function:
> [
] Measurement Options [OK] Oil Flow calc.
[OK].
Performing the measurement:
1. Select the parameters Oil Clocking (of the oil nozzle) and Oil
pressure (no effect on calculation): [], [] [Change].
2.Enter values. [], [] and partly [], [] [OK].
- The calculated oil burner capacity (in kW) is displayed.
Options:
> [Options] Print: The readings from a record are printed.
> [Options] Save: The readings are saved in a record.
> [Options] Change unit: The unit for the oil flow can be
changed (kg/h > gal/h or gal/h > kg/h).