66
6.1.5. Programs
Five flue gas measuring programs can be set, saved and executed.
The Trigger function (trigger signal as start/stop criterion) is only
available for devices with the trigger input option.
Instrument settings cannot be changed if a program is
active or running.
The program Exhaust Gas (before + after cat) checks
whether the analyzer box is equipped with a fresh air valve.
If not, a measuring program with normal flue gas
measurement will be added, instead of the program
Exhaust Gas (before + after cat). A program Exhaust
Gas (before + after cat) without fresh air valve does not
show any sensible measuring results.
Activating the function:
> [ ] → Programs → [OK].
Activating/deactivating a program:
> Select the program: [▲], [▼] → [Enable] or [Disable].
- When activating a program: The program is activated and the
measurement type matching the program is opened.
Editing the measuring program:
Adjustable parameters:
Parameter Function
Measurement
program
Edit program name
Measurement
type
Select flue gas menu:
• Flue gas
• Flue gas + m/s
• Flue gas ∆P
• Flue gas (before and after catalyst)
• Solid fuel
Reading per
mean value
With mean value Yes only mean values will be
saved.