EasyManuals Logo

Thermo King SR-2 SmartReefer2 User Manual

Thermo King SR-2 SmartReefer2
431 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #247 background imageLoading...
Page #247 background image
Section 5 – SR-2 Diagnostics
85 FORCED UNIT OPERATION
Page 1 of 1
Alarm Type
Check Alarm
Associated Alarm
Codes
Alarm Code 26 Check Refrigeration Capacity
How Alarm is Set
This alarm is set only if an alert low refrigeration capacity alarm occurs while the unit is operating in the reduced
capacity state.
How Alarm is Cleared
This alarm clears automatically if the condition is resolved.
Considerations
1. This alarm is a secondary alarm that is set along with the associated primary alarm.
2. This alarm indicates that the unit was forced to a different operating mode than would normally be
implemented under the existing conditions. This can occur as result of low coolant temperature or high
compressor temperature. It indicates that normal unit operation has been over-ridden, (i.e., the discharge
pressure setpoint has been reduced). The alarm is only set if a low cooling capacity condition occurs while
the unit is in reduced capacity mode.
Diagnostic Procedure
Check for associated alarms and repair as required.
5-65
02 February 2005

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King SR-2 SmartReefer2 and is the answer not in the manual?

Thermo King SR-2 SmartReefer2 Specifications

General IconGeneral
BrandThermo King
ModelSR-2 SmartReefer2
CategoryControl Systems
LanguageEnglish

Related product manuals