Section 5 – SR-2 Diagnostics
54 TEST MODE TIMEOUT
Page 1 of 1
Alarm Type
Shutdown Alarm
Associated Alarm
Codes
None
How Alarm is Set
1. This alarm is set if the unit has been in the same Service Test Mode function for 15 minutes.
2. This alarm is set if the unit has been in the same Interface Board Test Mode function for 15 minutes.
How Alarm is Cleared
This alarm is manually cleared.
Diagnostic Procedure
1. While the unit is in Service Test Mode, if no other function is selected within 15 minutes, the unit shuts
down and records Alarm Code 54. Clear the alarm and re-enter Service Test Mode, if necessary, to
complete the diagnosis or repair.
5-55
02 February 2005