Section 3 – SR-2 Software Description
Continuous Door Open Timeout
Micro Rev
All
HMI Rev
All
Choices
Off, 1 hour to 4 hours in 10-minute
increments
Factory Set
Off
Exceptions Only appears if Continuous Door
Open Forces = Off.
Description This feature allows the unit to restart
if the door open time exceeds the set limit.
Door Open Timeout for the selected range can be
set to Off or for a time limit from 1 to 4 hours, in 10-
minute increments. If set to Off, the unit will remain
off until the door is closed. If a time period is
selected the unit will restart and run 4 seconds after
the time period elapses. It will continue to run even
if the door is still open.