TOMARK, s.r.o.
Airplane Maintenance Manual
Chapter 05 Inspection and Maintenance
Issue: 04.APR 2016 Page 33
Scheduled Inspection
(50 h)
100 h/
annual
as
specified
Visually check the condition and attachment of the expansion
tank on the firewall.
Fuel System
Visually check the condition of the fuel hoses, connection of
the fuel hoses, their attachment and tightening. Replace
mechanically damaged, cracked or hardened hoses.
1
Visually check the fuel filter for dirt. Replace the fuel filter, if
it is clogged.
1
Exhaust System
Visually inspect flanges and stack-pipes.
(Exhaust stack attachment studs & nuts are prone to loss of
torque due to vibration and thermal expansion.)
1
Check EGT sensors for proper installation.
1
Visually inspect muffler and additional muffler for cracks,
leakage and security of attachment.
1
Engine Controls
Check throttle control for proper attachment, full travel,
freedom and smoothness of movement.
1
Clean and lubricate Bowden cable. Refer to Luprication plan.
500h/
5 Years
Inspect all wiring connected to the engine, regulators and
accessories for attachment, leads, chafing etc.
1
Inspect all firewall-mounted items for security of attachment.
1
Check battery for general condition, recharge as required.
Apply a thin layer of grease to the battery connections.
1
Inspect battery cables for signs of corrosion or cracks. Check
cable routing and attachment.
1
1
First 25 hours of operation for new or overhauled engine
Issue: 25.APR 2017