TOMARK, s.r.o.
Airplane Maintenance Manual
Chapter 05 Inspection and Maintenance
Issue: 04.APR 2016 Page 49
Perform Full Throttle Test Check.
Check brakes at full throttle
Check Idle RPM (refer to ROTAX 912 Operators Manual).
Fuel pressure within limit over complete RPM range both
pumps individual and in combination.
Check battery and power generation.
Perform maintenance check flight according to
05-21
Maintenance Check Flight
Make appropriate aircraft and engine logbook entries for
scheduled power plant service.
Ensure all Maintenance Record log-book entry’s required are
complied with before the aircraft return to service.
File all documents e.g. inspection report, ground run report
Forms and tags in aircraft history file.
05-20-02 Lubrication Chart
Three types of lubricants are used which are recommended:
LPS1 – Non-fat lubricant
Basic characteristics: dissolve fat and oils repels oil, dust and
sediments
creates dry, thin lubricated layer quickly penetrates and removes
moisture loosens rusted and seized parts; offers short term corrosion
protection safe for all surfaces
LPS2 – Strong industrial lubricant
Basic characteristics: creates everlasting thin oil layer; usage on outer
and inner devices; increased corrosion protection; expels moisture;
First 25 hours of operation for new or overhauled engine