Clearing the NVRAM
P/N 7010-0557 www.topconpositioning.com
4-19
Clearing the NVRAM of your receiver will not delete any files
already recorded in your HiPer Lite’s memory. However, it will
reset your receiver to factory default values.
In addition, the NVRAM keeps information about the receiver file
system. Note that after clearing the NVRAM, the receiver's STAT
LED will flash orange for a few seconds indicating that the receiver
is scanning and checking the file system. Firmware versions 2.2p1
or higher keep the spread spectrum modem on after clearing the
NVRAM.
Using MINTER to Clear NVRAM
1. Press the power key to turn off the receiver.
2. Press and hold the FN key.
3. Press and hold the power key for about one second.
Release the power key while continuing to hold the FN
key.
4. Wait until the STAT and REC LEDs are green
5. Wait until the STAT and REC LEDs blink orange.
6. Release the FN key while the STAT and REC LEDs blink
orange.
Using PC-CDU to Clear NVRAM
1. Connect your receiver and computer. See “Connecting the
Receiver and a Computer” on page 2-11 for this procedure.
2. Click ToolsClear NVRAM (Figure 4-14). The REC
LED flashes green and red; the STAT LED flashes red.
Figure 4-14. Clear NVRAM with PC-CDU
The receiver automatically disconnects when finished.