5-4
Problem
The receiver does not lock on to satellites for a long period of
time.
Causes Solutions
The receiver stores an
old almanac.
Update the almanac.
See “Collecting Almanacs” on
page 2-43.
Problem
The receiver tracks too few satellites.
Causes Solutions
The elevation mask
value is too high (e.g.,
above 15 degrees).
Lower the elevation mask.
See page 2-25 for information on
setting the elevation mask.
The survey is
conducted near
obstructions (tree
canopy, tall buildings,
etc.).
Check that the Multipath Reduction
boxes have been enabled.
1. Connect your receiver and a
computer and start PC-CDU. See
“Connecting the Receiver and a
Computer” on page 2-11.
2. Click Configuration
AdvancedMultipath
Reduction and enable the two
boxes.
Move to an area free of obstructions, if
applicable.