Specifications
Topcon HiPer Lite and HiPer Lite+ Operator’s Manual
B-6
Operating time With radio OFF:
~23.5 hours for the HiPer Lite
~19 hours for the HiPer Lite+
With radio ON and receiving only:
~19 hours for the HiPer Lite
~16 hours for the HiPer Lite+
With radio ON and transmitting 0.25 Watts only:
~15 hours for the HiPer Lite
~14 hours for the HiPer Lite+
With radio ON and transmitting 1 Watts only:
~13 hours for the HiPer Lite
~10 hours for the HiPer Lite+
External power 1 port
Input voltage 6 to 28 V DC (for work)
9 to 28 V DC (for charge battery)
Minimum Charge Current <=2 Amp
Consumption Typical: 2.5W
Maximum: 2.7W
On-board Backup battery for timekeeping and almanac data
storage; 10 years minimum operation
Environment
Operating
temperature
-30 C° to + 60 C° with batteries
Storage temperature -40 C° to +75 C° with batteries
Physical
Enclosure Aluminum extrusion, rainproof
Color Topcon Yellow
Dimensions W:159 x H:88 x D:172 mm
Weight 1.74 kg
Table B-1. Receiver Specifications (Continued)