LightSwitch(Optional)
POSITIONCLOSED
CIRCUITS
ON
2+1,5+4
OFF
2+3,5+6
Theoptionallightswitchislocatedonthecontrolpanelandhas2positions:
OFF,andON.
TestingtheLightSwitch
1.ParkthemachineonalevelsurfaceandsetthekeyswitchtotheOFF
position.
2.Disconnectthebatterynegative(-)cableatthebattery;refertoRemoving
andInstallingtheBattery(page6–29).
3.Lowertheoperatorcushion.
4.Disconnectthewireharnessconnectorfromtheswitch.Checktheswitch
andtheharnessconnectorfordamageorcorrosionandcleanorrepairif
necessary.Removetheswitchfromthecontrolpanelifnecessary.
5.Useamultimeter(ohmssetting)andtheprecedingtabletodetermine
whethercontinuityexistsbetweenthevariousterminalsforeachswitch
position.
6.Replacetheswitchifnecessary.
7.Iftheswitchtestscorrectlyandacircuitproblemstillexists,checkthewire
harnesses;refertoAppendixA(pageA–1).
8.Installtheswitchandconnectthewireharnessaftertesting.
9.Connectthebatterynegative(-)cableatthebattery.
ElectricalSystem:TestingtheElectricalComponents
Page6–18
FieldPro®6040
22267SLRevA