ServicingtheLaserLevelControlManifold(Optional)
g415966
Figure64
1.Coilnut(2each)6.#4zero-leakplugwithO-ring
2.Solenoidcoilw/diode7.Orice0.028inchOR
3.SolenoidvalveSV8.Solenoidcoil(2each)
4.Manifoldblock9.Coilspacer
5.PilotedvalveEP
10.ProportionalvalveSP
Forcartridgevalveserviceprocedures,refertoServicingtheCartridgeValves
(page5–97).
Theportsonthelasercontrolmanifoldaremarkedforeasyidenticationof
componentsandconnections.Example:SVisthelocationforthesolenoidvalve
andSPisthelocationforthesolenoidcontrolledproportionalvalve.
Thelasercontrolmanifoldincludeseveralzero−leakplugs.Theseplugshave
ataperedsealingsurfaceontheplugheadthatisdesignedtoresistvibration
inducedplugloosening.Thezero−leakplugsalsohaveanO−ringasa
secondaryseal.Ifremovingazero−leakplugisnecessary,lightlyraptheplug
headusingapunchandhammerbeforeusingahexwrenchtoremovetheplug:
theimpactwillallowplugremovalwithlesschanceofdamagetothesocket
headoftheplug.Discard,donotreusezero-leakplugs.Tightentheplugstothe
torquevalueprovided.