TestingtheLiftandTiltAngleCircuitsReliefValve(RV1)Pressure
g417890
Figure37
LiftCircuitReliefValve(RV1)Pressure
Thereliefvalvefortheliftcircuits(RV1)islocatedinthecontrolvalve.Iflift
operationsperformpoorly,performthegearpumpowtest;refertoT estingthe
LiftandTiltAngleCircuitsGearPumpFlow(page5–35).
SpecialEquipmentRequired:
PressureGauge(10,350kPa(1500psi)capacity)
Non-contacttachometer(phototach)
TestProcedure
1.Parkthemachineonalevelsurface,loweranyattachments,engagethe
parkingbrakeandsetthekeyswitchtotheOFFposition.
2.ReadandadheretotheinformationprovidedinTestingtheHydraulicSystem
(page5–19).
3.Removethehood.
4.InstallapressuregaugeatthecontrolvalveP1porttesttting.
HydraulicSystem:TestingtheHydraulicSystem
Page5–38