LaserLevelControlManifold(Optional)
g415781
Figure63
1.Elbowtting3.Manifoldbracket5.Elbowtting
2.Manifoldassembly4.Straighttting(2each)
RemovingtheLaserLevelControlManifold
RefertoFigure63forthisprocedure.
1.Parkthemachineonalevelsurface,loweranyattachments,engagethe
parkingbrake,setthekeyswitchtotheOFFpositionandremovethekey
fromthekeyswitch.
2.Removethehood.
3.ReadandadheretotheinformationprovidedinGeneralPrecautionsfor
RemovingandInstallingtheHydraulicSystemComponents(page5–46).
4.Labelanddisconnectwireharnessconnectorsfromthecartridgevalvecoils.
5.Topreventcontaminationofthehydraulicsystemduringmanifoldremoval,
thoroughlycleanexteriorofthemanifold,hydrauliclineconnections,and
ttings.
6.Labelanddisconnectthehydrauliclinesfromthemanifoldandinstallcaps
orplugsontheopenhydrauliclinesandttingstopreventhydraulicsystem
contamination.
HydraulicSystem:ServiceandRepairs
Page5–94