6.4.5 Setting range correction
The values of the background peak / text peak in the range correction can be switched to “varied” or
“fixed” in the following codes.
If they are fixed, the range correction is performed with standard values.
The values of the background peak affect the reproduction of the background density and the values of
the text peak affect that of the text density.
< Adjustment Mode (05) >
Make a test copy and compare the image obtained with the current settings; if necessary, make
adjustment using the following procedure.
<Procedure>
Procedure is same as that of P.6-25 "6.4.2 Density adjustment".
6.4.6 Adjustment of smudged/faint text
The smudged/faint text can be set at the following codes.
< Adjustment Mode (05) >
<Procedure>
Procedure is same as that of P.6-25 "6.4.2 Density adjustment".
Original mode
Item to be
adjusted
Remarks
Text/
Photo
Text Photo
Color
Docum
ent
User
Custom
7283 7284 7285 7289 7236 Automatic density
mode
0: Background peak / fixed.
1: Background peak / varied
7286 7287 7288 7290 7237 Manual density
mode
Original mode
Item to be adjusted Remarks
Text/Photo Text
User
Custom
7097 7098 7252 Adjustment of smudged/faint
spotted text
When the value increases, the faint
text is improved.
When the value decreases, the
smudged text is improved.
Acceptable values: 0 to 4 (Default: 2)
Note:
Remember the image
specifications and life span of
the replacing parts may not
meet the standard when the
setting value is changed from
the default value.

Table of Contents