6.14.7 RADF opening/closing switch adjustment
Adjust the bracket position so that the sensor is turned ON when the height “J” becomes 145 mm or
less (within the empty weight falling limit).
Fig. 6-91
(1) Take off the RADF rear cover.
( P.4-117 "4.12.3 RADF rear cover")
(2) Loosen the fixing screw of the bracket. Slide
the bracket vertically using the scale as a
guide to adjust the position where the switch
is turned ON.
(3) Tighten the fixing screw of the bracket. Install
the RADF rear cover.
Fig. 6-92