e-STUDIO556/656/756/856(Ver03) © 2012 TOSHIBA TEC CORPORATION All rights reserved
REPLACEMENT OF PC BOARDS / HDD
9 - 24
(9) Check that the installed license is displayed on the license list.
If there are any other licenses to be installed, repeat from step (13). If there are no other licenses
to be installed, press the [CLOSE] button, and then turn the power OFF.
[L] Enable HDD encryption
If you use the HDD encryption function, follow the procedure below.
(1) Start up with the Setting mode (08).
(2) Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [ENTER] button without entering anything.)
(3) Enable the HDD encryption function. Set the value of 08-8911 to "3", or the value of 08-8911 to
"1" and 08-9379 to "1" or "2".
(4) Turn the power OFF.
[M] Adjust image quality
(1) Start up with the Setting mode (08).
(2) Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [OK] button without entering anything.)
(3) Perform “Data transfer of characteristic value of scanner” (05-3203).
(4) Perform “Automatic gamma adjustment” <PPC> (05-7165).
P.6-24 "6.4.1 Automatic gamma adjustment"
(5) Turn the power OFF.
[N] Initialize settings when FAX Unit (GD-1250) is installed
(1) Turn the power ON while pressing [0] and [8] simultaneously.
(2) Enter the password, and then press the [OK] button.
(If the password is not set for Service, press the [OK] button without entering anything.)
(3) Set the destination of FAX (08-9001).
(4) Turn the power OFF.
(5) Start up with the FAX Clearing Mode (1*).
(6) Perform the FAX Set Up (1*-100).
(7) Turn the power OFF and then back ON.
(8) Set the dial type according to these buttons: [USER FUNCTIONS] -> [ADMIN] -> [FAX] ->
[INITIAL SETUP]
[O] Set date and time
Set the date and time according to these buttons.
[USER FUNCTIONS] → [ADMIN] → [GENERAL] → [CLOCK] → [DATE/TIME]