11
© 2012 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO556/656/756/856(Ver03)
FIRMWARE UPDATING
11 - 25
(8) “Update Completed.” is displayed at the bottom of the LCD screen after the updating is
completed properly.
Fig. 11-3
• “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not
completed properly. “Failed” appears next to the failed item on the status display. In this case,
shut down the equipment after all the updates are stopped (when either “Completed” or
“Failed” is displayed for each item), and then check the following.
- Do the USB media meet the conditions to be used for updating?
- Is the data file written properly on the USB media?
- Are the USB media installed properly?
- Do the USB media and equipment operate properly?
• When an error occurred and the update failed, “Update Failed” or “Failed” appears on the
screen and an error code appears next to the message. The content of each error code is
shown below.
OS update Error
Error
number
Error content
O01
FROM writing failed
O02
FROM verification error
O03
File operation error
O04 SRAM flag set error
O05 Electronic key data backup error
O06
Device error
HDD update Error
Error
number
Error content
H01
File creation error
H02
File decompression error
H03
Partition mount error
H00
Other errors