100-11672 - Rev D Page 185
2. Replace Encoder Sensor.
3. Replace Operation Panel PCB.
4. Replace DC Power PCB Unit.
Motor 24V was not turned OFF correctly
1. Replace DC Power PCB Unit.
2. Replace Printer Controller PCB.
Printhead 5V was not turned OFF correctly
1. Replace DC Power PCB Unit.
2. Replace Printer Controller PCB.
Printhead 24V was not turned OFF correctly
1. Replace DC Power PCB Unit.
2. Replace Printer Controller PCB.
VHTM of the fuse to be blown
1. Replace DC Power PCB Unit.
2. Replace Printer Controller PCB.
For Detail Codes 05 to 09, the occurrence of the error is
stored in
memory, so the same error will recur next time Printer starts.
To
clear the error, (Service Utility > Parts Replacement > Release
the
Error) and then restart Printer.
Printer Controller PCB 3.3V was not turned ON
correctly.
Replace DC Power PCB Unit.
Motor 24V was not turned ON correctly
Replace DC Power PCB Unit.
Printhead 5V was not turned ONcorrectly
Replace DC Power PCB Unit.
Printhead 24V was not turned ON correctly
Replace DC Power PCB Unit.
For Detail Codes 11 to 15, the occurrence of the error is
stored in memory, so the same error will recur next time
Printer starts. To clear the error, (Service Utility > Parts
Replacement > Release the Error) and then restart Printer.
05: Printhead Position Error
1. Check Printhead Lifter part movement.
2. Replace Print Module.