TTP-245 / TTP-343
5
Gap/Black Mark
Sensor Calibratio,
Label Length
Measurement, Self
Test and enter Dump
Mode
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and
blinking. (Any amber will do during the 5 blinks).
The LED color will be changed as following order.
Amber red (5 blinks) amber (5 blinks)
green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green
It calibrates the sensor and measures the label
length and prints internal settings then enter the
dump mode.
Note:
Please select gap or black mark sensor by GAP or
BLINE command prior to calibrate the sensor.
For more information about GAP and BLINE command,
please refer to TSPL2 programming manual.
Printer Initialization
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green after 5 amber
blinks. (Any green will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks)
green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green
Note:
Always do gap/black mark sensor calibration after
printer initialization.
Force Black Mark
Sensor Calibration
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5
green blinks. (Any green/amber will do during the 5
blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks)
green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green