Cables Standard cable length Maximum cable length Wire gauge
Floor sensor cable to thermostat 5 m 5 m 0.75 mm²
Outdoor sensor cable to thermostat - 5 m Twisted pair
Cable from relay switch to room
controller GPI input
2 m 20 m Room controller: Up to 4.0 mm²
solid, or 2.5 mm² flexible with
ferrules
Relay: 1.0 mm² to 4.0 mm²
18.3 Uponor Smatrix Wave PULSE room controller layout
D F
C EB G H IA
CD0000118
Item Description
A Transformer, 230 V AC 50 Hz power module
B Fuse (T5 F3.15AL 250 V)
C Optional inputs and outputs (pump and boiler management)
D Channel registration buttons
E LEDs for channels 01 – 06
F Quick connectors for actuators
G Power LED
H Uponor Smatrix Wave M-262 (optional slave module)
I End cap