12.6 Reset the controller
SI0000177
10 s
Note
Make sure the room controller is in run mode. If it is in
registration or forced mode, press and hold the OK
button for about 5 seconds or until the LEDs turn off.
Note
Resetting the room controller removes all registration
information and settings from the room controller.
Registration of thermostats and system devices are once
again required.
Note
If a room controller has been connected to a
communication module, disconnect the communication
module and restore it to sub room controller state by
factory reset.
Existing sub room controllers in the system must then
either, reset system device channel 01, or register to
another master room controller.
Note
If resetting a sub room controller, all remaining sub room
controllers must be unregistered from the master room
controller (system device channel 1). Register the
remaining sub room controllers to the master room
controller again when finished.
If problems, such as incorrect channel registration exist, reset the
room controller.
To reset the room controller:
1. Press the <, OK, and > buttons simultaneously (for about
10 seconds) until the power LED flashes, and all channel LEDs
turn off. All parameters are erased and run mode has been
activated.
12.7 Unregister room controller
channels
Note
Make sure the room controller is in run mode. If it is in
registration or forced mode, press and hold the OK
button for about 5 seconds or until the LEDs turn off.
When a channel is inaccurately registered or if a thermostat
registration needs to be redone, it is possible to remove the current
registration from the room controller.
Unregister a room controller channel
1. Enter registration mode
3 s
SI0000065
Press and hold the OK button on the room controller until the LED for
channel 1 (or the first unregistered channel) flashes red.
2. Select a channel
SI0000049
1 65432
Use buttons < or > to move the pointer (LED flashes red) to the
channel to unregister (solid green LED).
3. Unregister the channel
5 s
SI0000156
Press the < and > buttons simultaneously until the LED for the
selected channel starts flashing red (about 5 seconds).
4. Exit registration mode
3 s
SI0000078
Press and hold the OK button on the room controller until the green
LEDs turn off to end registration and return to run mode.
Unregister a system device channel
1. Enter registration mode
3 s
SI0000065
Press and hold the OK button on the room controller until the LED for
channel 1 (or the first unregistered channel) flashes red.
Uponor Smatrix Wave PULSE
|
Installation and operation manual
|
77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Wave PULSE and is the answer not in the manual?

Uponor Smatrix Wave PULSE Specifications

General IconGeneral
TypeWireless Temperature Controller
Communication ProtocolRF (Radio Frequency)
CompatibilityUponor Smatrix Wave system
Operating Temperature Range0°C to 50°C
DisplayLCD
ControlWireless

Related product manuals