Components of the relay module
The illustration below shows the relay module and its components.
A B
CD0000034
Item Description
A Uponor Smatrix Wave M-161
B Mounting material
Uponor actuators
Uponor actuators are mounted on top of the manifold valves and is
operated using either on/off signals or pulse width modulation (PWM)
signals.
A B
CD0000035
A Actuator has closed the valve – empty indicator
B Actuator has opened the valve – white indicator
On/off control
When installing a system with on/off control, manual balancing of the
system is required.
As soon as the temperature measured at a thermostat is lower
(heating mode) or higher (cooling mode) than the setpoint
temperature, a demand to change the room temperature is created
and sent to the room controller. The room controller will open the
actuators according to current operating mode and other settings.
Once the set temperature is reached, this information is sent and the
actuators are closed. The indicator on the actuator shows, with a
white bar, how much it is opened. If indicator (white) is fully shown it
is fully opened, no white bar shown means that the actuator is closed.
Time to open and close an actuator may take a couple of minutes.
PWM control
Note
Autobalancing can be used in combination with hydronic
balancing.
PWM control is used when the Autobalancing function is active.
When installing a system with PWM control, all balancing valves can
be fully opened, the system is balanced automatically.
See Autobalancing, Page 13, for more information.
3.4
Accessories
Uponor offers a wide variety of accessories for use with the standard
portfolio.
A
B C D E
F G
CD0000036
Item Component Description
A Attachment options for
thermostats T163, T165,
T166, and T168
Table stand
B Screws
C Uponor Smatrix T-X A-1XX
(wallframe T-X A-1XX)
Wall frame for covering larger
area of the wall than original
back plate. Used at installation
of thermostats T163, T165,
T166, and T168
D Uponor Smatrix S-113
(outdoor sensor S-113)
Outdoor sensor for use with
thermostats T163, T166,
T-168 and T169
E Uponor Smatrix S-114
(floor/remote sensor S-114)
Floor/remote sensor for use
with thermostats T-161, T163,
T166, T-168 and T169
F Uponor Heating/Cooling relay Relay for connecting external
voltage signal from a heating/
cooling source, such as a heat
pump, to a room controller
input.
G DIN rail DIN rail for use with Uponor
Smatrix Wave room controllers
3.5 Functions
Note
Setting up a system with a communication module
requires a mobile device (smart phone/tablet).
The Uponor Smatrix room controler is used to operate an underfloor
heating and/or cooling system in a house.
The room controller can also control heating via electrical underfloor
heating using an external relay, and/or radiators using thermostatic
heads.
The thermostats registered to the room controller is used to control
the actuators mounted on top of the manifold valves.
As soon as the temperature measured at a thermostat is lower
(heating mode) or higher (cooling mode) than the setpoint
temperature, a demand to change the room temperature is created
and sent to the room controller. The room controller will operate the
actuators according to current control mode and settings. This will
manage the flow to the floor loops in the room and adjust the room
temperature. Once the set temperature is reached, this information is
sent to the room controller and the demand is met.
12
|
Uponor Smatrix Wave PULSE
|
Installation and operation manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Wave PULSE and is the answer not in the manual?

Uponor Smatrix Wave PULSE Specifications

General IconGeneral
TypeWireless Temperature Controller
Communication ProtocolRF (Radio Frequency)
CompatibilityUponor Smatrix Wave system
Operating Temperature Range0°C to 50°C
DisplayLCD
ControlWireless