If the output frequency goes under/over the set limit (ID316) this function generates a
message via digital output depending
1.
on the settings of parameters ID312 to ID314 (applications 3,4,5) or
2.
on to which output the supervision signal 1 (ID447) is connected (applications 6 and 7).
Brake control uses different output functions. See ID445 & ID446.
316 OUTPUT FREQUENCY LIMIT SUPERVISION VALUE 234567 (2.3.11, 2.3.4.2, 2.3.2.2)
Selects the frequency value supervised by parameter ID315.
f[Hz]
t
21 RO1
22 RO1
23 RO1
21 RO1
22 RO1
23 RO1
21 RO1
22 RO1
23 RO1
Example:
ID316
ID315 = 2
Fig. 40: Output frequency supervision
319 DIN2 FUNCTION 5 (2.2.1)
This parameter has 14 selections. If digital input DIN2 need not be used, set the parameter
value to 0.
PARAMETER DESCRIPTIONS VACON · 263
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM