7.2 CONTROL I/O
1
6
2
3
4
5
18
19
20
12
7
13
8
9
10
14
15
16
21
22
23
11
17
24
25
26
Fault
+
-
AO1-(GND)
DO1
+24 V
GND
GND
DIN1
DIN2
DIN3
DIN4
DIN5
DIN6
R O1
R O1
R O1
CMA
CMB
R O2
R O2
R O2
OPTA1
OPTA2
Terminal Signal Description
+10V
ref
AI1+
AI1-
AI2+
AI2-
+24V
Reference output
I/O Ground
Analogue input 2
Current range 0—20 mA
Programmable (P2.2.1.9)
Control voltage output
I/O ground
Place A: Start/Stop
Programmable (G2.2.6)
Interlock 1
Programmable (G2.2.6)
Interlock 2
Programmable (G2.2.6)
Place B: Start/Stop
Programmable (G2.2.6)
Jogging speed selection
Programmable (G2.2.6)
Control place A/B selection
Programmable (G2.2.6)
Common for DIN 1—DIN 3
Common for DIN4—DIN6
Control voltage output
I/O ground
Analogue output 1
Output frequency
Programmable (P2.3.3.2)
Digital output
READY
Programmable (G2.3.1)
Open collector,
I50 mA, U48 VDC
Relay output 1
Aux/Autochange 1
Programmable
(G2.3.1)
Relay output 2
Aux/Autochange 2
Programmable
(G2.3.1)
**)
Range 0—20 mA/R
L
,
max. 500 Ω
AO1+
Analogue input 1 PID reference
from I/O
Default reference from keypad P3.4
Ground for reference and
controls
Analogue input 2 PID
actual value 1
Start signal for control place A
PID Controller.
Contact closed = Interlock used
Contact open = Interlock not used
Contact closed = Interlock used
Contact open = Interlock not used
Contact open = Control place A is
active Contact closed = Control
place B is active
Contact closed = Jogging speed
active
Contact closed = Start
Voltage for potentiometer, etc.
Analogue input 1
Voltage range 0—10V DC
Voltage for switches,
etc. max 0.1 A
Voltage for switches (see #6)
Ground for reference and controls
Connect to GND or +24 V
Connect to GND or +24 V
Ground for reference and controls
*)
*)
2 wire
Transmitter
Reference potentiometer,
1-10kΩ
Actual
value
(0) 4-20
mA
Fig. 19: Pump and fan control application default I/O configuration and connection example (with
2-wire transmitter)
PUMP AND FAN CONTROL APPLICATION VACON · 197
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM
7

Table of Contents

Other manuals for Vacon NX series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX series and is the answer not in the manual?

Vacon NX series Specifications

General IconGeneral
Product typeAC Drive
Output voltage range0-Uin
Frequency range0-500 Hz
Enclosure classesIP00, IP21
Mounting typesWall
Braking chopperIntegrated or external
EMC filterBuilt-in or external
Control modesScalar, Vector
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Communication optionsModbus, Profibus, CANopen, Ethernet
Ambient temperature range-10°C to +50°C
Cooling methodAir-cooled