MC122 - MCP-4J Control Unit Section 5 - Operation
67
Gluing Mode - Continued
Auto Glue - Applies a strip of adhesive based on the length of the scanner signal. Input the start delay (length from
the leading edge of the product to the beginning of the glue line) and the end delay (the end of the glue line to the
trailing edge of the product).
The Auto Glue Glue Mode is available in the following
applications: Corrugated, Folding Carton, Packaging, Core
Winding, Timer, Valve Driver and Others.
Scanner Lockout
(Available in Corrugated, Folding Carton, Envelope, Packaging, Timer, Core Winding, and Others)
Scanner Lockout - Enter a product length to act as a scanner lockout when holes, writing, or other items produce a
false trigger by the scanner.
Valve to Scanner Distance
(All Applications)
Valve to Scanner Distance - Scanner Number - The number of the assigned scanner.