Section 5 - Operation MC122 - MCP-4J Control Unit
80
Helpful Hints about Pressures
The four pressures/speeds are dependent upon each other. For example, the first speed setting can never be greater
than the second speed setting, and the second speed setting can never be greater than the third, and so on. Also, the
second speed setting can never be less than the first speed setting, the third speed setting can never be less than the
second speed setting, and so on. Therefore, if you cannot set speeds to where you want them (the Plus/Minus Arrow
Buttons will not increase or decrease the setting), check all four of the settings. Use the Left Arrow and Right Arrow
Buttons to move through all pressures/speeds and check them. Reset them as necessary using the Plus/Minus Arrow
Buttons. You can also go back to factory defaults by pressing the Erase Button until the setting will no longer change.
Diagnostic Button
(All Applications)
Total Products/Products per Hour
The first diagnostic screen shows the total number of products and the number of products per hour. The total number
of products count can be reset to zero by pressing the Erase Button.