VEMCO VR100 Manual 28 May 2018 38
4.4.3 Get Detection or Pings Stats
Receivers can report a rough number of detections or pings stored in the memory. This can be the total
number since the receiver was last initialized, the amount since the last data offload, or the amount since the
last mark was made in the file.
NOTE: The detection counts and times are rounded approximations; use VUE to obtain exact values (or
FATHOM, for the HR2). The larger the count the greater the approximation. Exact amounts will be shown
when the receiver is connected to VUE via Bluetooth (or FATHOM, for the HR2), as explained in the
receiver manual.
STEP 1
Select Status…” from the list, or press the “1”
button on the keypad to display the list of status
options (on right).
STEP 2
Select “Detections” (#3) to get an idea of the
number of detections stored in the memory.
STEP 3
Select either Total Detects” (#1), Since Offload (#2), or “Since
Marking” (#3) based on the descriptions below. In either case, the
VR100-200 will request the information from the receiver, displaying the
“T-” countdown during the communication steps (transmission and
reception). NOTE: For HR2 receivers, you can retrieve PPM, HR, or
PPM+HR detections, under each of the options below.
1 Total Detects displays the number of detections stored in the
receiver since it was last initialized and the memory was erased.
Initialization can only occur while the receiver is communicating with
VUE software. This is the total number of detections stored in the
receiver, old (offloaded) and new (not offloaded).
2 Since Offload reports the number of detections stored in the
receiver since the last data offload to VUE. This is the number of
detections that have not been offloaded to VUE, or are new
detections.
3 Since Marking reports the number of detections stored since the last “Mark” command was sent.
STEP 4
Use the MENU button to return to the main transponding screen.
1 Status...
2 Settings...
3 Acoustic Release
Select
1 Total Detects...
2 Since Offload...
3 Since Marking...
Select
MENU
VR2AR:000001 170m
Detects: 186,300
Last: Jun3/14 11:02
(TOTAL) Resend
1 Get Health
2 Get Range
3 Detections...
Select
VR2AR:000001 170m
Detects: 3,850
Last: Jul15/14 17:38
(NEW) Resend