A100K11194
Turbine Station Conguration Guide
Enable SNMP v2c
- This enables reading of the MIB using SNMP version 2c.
Community string
- Enter a text string used as a password for authentication.
Allowed Network
- This is used, together with the network mask, to determine the allowed network for reading the
MIB on the station.
- The IP address is entered in regular dot notation, e.g. 10.5.2.100. For example with an allowed
network 10.5.2.0 and a network mask of 24, any station with an IP address in the range
10.5.2.0 to 10.5.2.255 can access the MIB.
Name
- SNMP name string (sent as sysName OID in traps)
Location
- SNMP Location string
Contact
- SNMP Contact string
SNMP Trap and Informs Settings
Trap receiver
- Enter the IP address of the server receiving SNMP traps. This is disabled if the eld is left
empty.
Inform receiver
- Enter the IP address of the server receiving SNMP informs. This is disabled if the eld is left
empty.
SNMPCustomCongurationFile
- Upload the custom snmpd.conf le that will be used when running SNMP. The uploaded le
will be preserved after the station has been upgraded to a newer rmware version.
Enable SNMP Traps
IP-Station Started
- If enabled, the station will send an SNMP trap when the station application is started.
Registration Successful
- If enabled, the station will send an SNMP trap when successfully registered in the SIP domain.
Registration Failed
- If enabled, the station will send an SNMP trap if registration in the SIP domain failed.
Call Connected
- If enabled, the station will send an SNMP trap when a call is connected.
Call Connect Failed
- If enabled, the station will send an SNMP trap if a call to the station fails to connect for any
reason (busy etc.).
Call Disconnect
- If enabled, the station will send an SNMP trap when a call is disconnected.
Dak Pressed
- If enabled, the station will send an SNMP trap when a DAK is pressed.