35: Event system 
_______________________________________________________________________________________________________ 
_____________________________________________________________________________________________________ 
© Virtual Access 2017 
GW1000 Series User Manual 
Issue: 1.9    Page 320 of 350 
va_eventd.@forwarding[0].eventName=LinkUp 
va_eventd.@forwarding[0].severity=warning-critical 
va_eventd.@forwarding[0].target=syslog1 
35.7.4  Forwarding using package options 
root@VA_router:~# uci export va_eventd 
config forwarding  
 option enabled ‘1’ 
 option className ‘ethernet’ 
 option eventName ‘LinkUp’  
 option severity ‘warning-critical’  
 option target ‘syslog1’ 
35.7.5  Forwarding table options 
UCI: va_eventd.<forwarding 
label>.enabled 
Opt: enabled 
Enables or disables event generation. 
UCI:  va_eventd.<forwarding 
label>.className 
Opt: className 
Only generate events with the given className. Available class 
names can be viewed using 'vae_cli -d' command. 
UCI:  va_eventd.<forwarding 
label>.eventName 
Opt: eventName 
Only generate events with the given className and the given 
eventName. The eventName is optional and can be omitted.