8: System settings 
_______________________________________________________________________________________________________ 
_____________________________________________________________________________________________________ 
© Virtual Access 2017 
GW1000 Series User Manual 
Issue: 1.9    Page 48 of 350 
Web Field/UCI/Package Option 
Sets the local time and syncs with browser. You can manually 
configure on CLI, using: 
date –s YYYY.MM.DD-hh:mm:ss 
Web: hostname 
UCI: system.main.hostname 
Opt: hostname 
Specifies the hostname for this system. 
 
Web: Timezone 
UCI: system.main.timezone 
Opt: timezone 
Specifies the time zone that the date and time should be 
rendered in by default. 
 
Web: n/a 
UCI: system.main.timezone 
Opt: time_save_interval_min 
 
Defines the interval in minutes to store the local time for use on 
next reboot. 
Table 14: Information table for general settings section 
8.2.2  Logging 
 
Figure 22: The logging section in system properties  
Web Field/UCI/Package Option 
Web: System log buffer size 
UCI: system.main.log_size 
Opt: log_size 
 
Web: External system log server 
UCI: system.main.log_ip 
Opt: log_ip 
 
External syslog server IP address. 
Web: External system log server port 
UCI: system.main.log_port 
Opt: log_port 
 
External syslog server port number.