EasyManua.ls Logo

Wachs Vitals - Page 59

Wachs Vitals
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5, Using Vitals Mobile-TC (TC-100 Controller): Valve Operation
E.H. Wachs Part No. 79-MAN-04, Rev. I 53
If connection is not detected
when the Vitals controller
screen opens, a message will
ask if you want to autocon-
nect. Tap Yes.
You can tap the Tap to con-
nect button to try to make a
connection to the valve oper-
ator using the saved port.
2.
The Torque field displays the current operating torque.
3.
The Highest field displays the highest torque level
during the current operation.
4.
The Limit field displays the current torque limit. (To
change the default torque limit setting, tap the
Settings
icon and go to the
Controller Settings tab.)
5.
The Count field displays the current position, in num-
ber of turns from the starting point (positive or nega-
tive).
6.
To override the automated exercising program and set
a starting direction, tap the
Direction button until either
RH or LH appears. Leave the question mark in the dis-
play for automatic direction control.
7.
The Turns field displays the total number of turns per-
formed, in both directions, during the current opera-
tion.
If you get a Transducer Error
message during operation,
there is something wrong
with the transducers or
cables. Operating with faulty
transducer readings could
cause valve damage. See
“Transducer Errors” at the
end of this section.
8.
Press START to begin the valve operation. The valve
exerciser will run in the selected mode. The button
will turn red and the text will change to
STOP.
9.
To turn the valve exerciser slightly in either direction
(for positioning or installing the valve key), tap and
hold on one of the
Jog buttons. The operator will turn
as long as you keep touching either of these buttons.
See Appendix A for a
description of the operating
modes.
10.
By default, the valve exerciser mode is EXER, which
runs the valve exercising protocol. You can also oper-
ate in Emergency Mode (
EMER) and Manual Mode
(
MAN). Tap the Mode button to switch modes.
11.
Press STOP to end the valve operation. The button will
blink white and green and the text will change to
START.
12.
To reset the valve operation readings and the operat-
ing defaults, tap and hold the
Reset button.
13.
Tap the Back button to go to the valve information
screen for the current valve and enter remarks or other
CAUTION
NOTE

Table of Contents