Stock Properties > Advanced Stock Setup
Recommended
Incremental Ad-
justment
Available RangeAdjustment Step
Increments
Default ValueOption / Setting
Determined by
test print output
10 to 200 %1100Black
Secondary Transfer Voltage Adjustment
Perform Auto Ad-
justment
10 to 300 %1150Side 1
Perform Auto Ad-
justment
10 to 300 %1150Side 2
Determined by
test print output
System Default
Multi Feed Sup-
port Table
Mis-Feed Support
Table
Forced Off
Custom 1 through
8
Distinct Selec-
tions Available
System DefaultTray Air Assist
---------Checked BoxEnable Tray Heat-
er
10%0 to 100 %1100Transfer Output
Adjustment for
Trail Edge
0.05%-0.50 to 0.50 %0.010.00Adjustment of
Paper Speed at
Transfer
1° or 2 °-10 to 10° C10Fuser Temperat-
ure Adjustment
0.1%-5.0 to 5.0 %0.10.0Fuser Speed Ad-
justment
5 or 10-40 to 40 Pulse10Aligner Roll Pres-
sure
0.3 mm-3.0 to 3.0 mm0.30.0Regi-Loop
Determined by
test print output
Available selec-
tions will be
based on the Pro-
files created by
the user
Distinct Selec-
tions Available
DefaultAlignment Profile
Xerox
®
Versant
®
3100 Press7-26
User Guide