The following table defines the media sizes, width ranges, and default NVM values that
can be set for the fuser.
Table 1: Bypass Connector Used for Default Paper Width NVM Settings
NVM Default ValueWidth RangeMedia SizeBypass Connect-
or
Range Num-
ber
980-330298.0 - 330.2 mm
(3.858 - 13.0 in.)
All paper widthsNone1
1800-2499
2704-298
0
180.0 - 249.9 mm
(lower limit)
270.4 - 298.0 mm
(upper limit)
A4 / Letter SEF
A3 SEF
A4 / Letter LEF
11 x 17 in.
Black Resistor
Type
2
3000-3100
3070-3302
300.0 - 310.0 mm
(lower limit)
307.0 - 330.2 mm
(upper limit)
SRA312 in. /
13 in.
Blue Type3
100.0 - 330.2 mm
(3.937 - 13.0 in.)
Custom4 See Note
Note
Refer to the System Administrator Guide for the procedure on how to reset NVM settings for
other widths not shown in this table.
Changing the Fuser Width ID
The press is installed with a default standard fuser type that is suitable for all media
sizes (paper widths). However, when removing the fuser module, you can optimize its
life and maintain the system’s image quality output by attaching a jumper connector
to the fuser assembly that identifies the specific paper width range to use. For information
and instructions, refer to Removing the Fuser Module.
If you plan to print jobs using a specific paper width, use this procedure to attach the
bypass connector for that fuser to the fuser assembly. This identifies to the system that
a different fuser is being used and only certain paper widths will be allowed to print.
The fuser types available are:
• 11 inch (A4 / Letter SEF) width fuser
• 12 inch (A3 SEF / A4 / Letter LEF / 304.8 mm) width fuser
• 13 inch (SRA 3/ 330.2 mm) width fuser
• Custom and other size papers
6-39Xerox
®
Versant
®
3100 Press
User Guide
Maintenance