Important
To identify the fuser type and set minimum and maximum NVM width values, inform
the system administrator. The administrator must set the NVM settings from Tools mode
on the press control panel. When using a bypass connector with the fuser, the press
detects the fuser type and width and confirms it is appropriate for the system.
Note
The bypass connectors required for each fuser width type are located in the
nationalization kit which come with the press. To order additional fusers for this product,
contact your Customer Support Center.
Warning
Before performing this procedure, power off the press and allow fifty minutes for the
fuser to cool down. Always observe the warning labels inside the press.
1. If required, have the system administrator update the NVM width range settings for
the fuser from Tools mode, and identify the specific width range of media that can
be run through the fuser.
Refer to the Default and Custom Paper Width Settings tables (in the Using the
Fuser NVM Read/Write Setting procedure) in the System Administrator Guide.
Always set the NVM settings before using the new fuser.
2. Open both the left and center front doors.
3. Locate the black fuser front cover.
4. Remove the fuser front cover by using the T10 Torx driver to unscrew the one
mounting screw at the center of the cover.
Xerox
®
Versant
®
3100 Press6-40
User Guide
Maintenance