1 Outline of INFORM
FS100 1.1 About INFORM
1-4
1.1.4 Variables to be Used in Instructions
Variables can be used as numeric data for the additional item of the
instructions in the standard and expanded instruction sets.
Also, the instructions in the expanded instruction set can use local
variables and array variables.
1.1.4.1 Set Value of Variable and Numeric Data
The unit of the numeric data for the additional item of the instruction
decides the set value of variable and the value of the additional item at
execution.
< Example >
TIMER tag (T=)
TIMER T=I000
When a variable is used for the numeric data of the TIMER tag, the unit
of numeric data is 0.001
seconds.
When 1000 is set for I000, the value when the instruction is executed is
1.00 seconds.
NOTE
The applicable variable differs depending on the
additional item.
The number of local variables to be used must be set in
the job header display. For setting the number of local
variables, refer to the FS100 Operator’s Manual “3.9.11
Editing Local Variables”.