2       INFORM Explanation
FS100 2.7   General-purpose Instruction :  TOOLOF
2-222
TOOLOF
Turns OFF the work instruction.
1. UNITn
Choose one of the tags from the Unit (Equipment).  These tags are valid 
for a system with multiple applications in which two or more general-
purpose applications are included.  These tags are not displayed when 
there is only one application.
(1) TOOLOF
Turns OFF the work instruction.
Turns ON the work end instruction (dedicated output relay 
#51531) and waits for the work end response (dedicated input 
relay #41131).  When the work end response is turned ON, the 
next instruction is carried out.
The work end response relay is designed to turn ON immediately 
after the output of the work end instruction.
SUBSET STANDARD EXPANDED APPLICATIONS
Available Available Available General-purpose
No Tag Explanation Note
1 UNITn Specifies the Unit  (Equipment). n: 1 to 2
UNIT1: UNIT1