2 INFORM Explanation
FS100 2.2 Control Instruction : SETUALM
2-63
SETUALM
Generates an alarm with any given number, name and subcode.
1. Alarm Code
Add the following tag.
SUBSET STANDARD EXPANDED
Not available Available Available
Function
Construction
SETULAM
SMODE=
I/ LI/ I[]
/LI[]
S/ LS/
S[]/ LS[]
1
" "
2
END
B/ LB/
B[]/ LB[]
B/ LB/
B[]/ LB[]
3
4
A
A
Constant
Variable number
Variable number
Byte type constant
Byte type constant
Variable number
Variable number
Character string
Explanation
No Tag Explanation Note
1 I Variable number/
LI Variable number/
I [Variable number]/
LI [Variable number]/
[Constant]
Specifies the integer type variable number. Number: 8000 to 8999