2 INFORM Explanation
FS100 2.1 I/O Instructions : PULSE
2-11
PULSE
The pulse signal is output to the general output signal only for the
specified time.
The PULSE instruction, without waiting for completion of the instruction,
executes the next one.
1. OT# (output number) / OG# (output group number) /
OGH# (output group number)
Choose one of the tags from the following table..
SUBSET STANDARD EXPANDED
Available Available Available
Function
Construction
PULSE
T=
Time (second)
END
6
OT# (
Output No.
)
OG# (
Output group
No.
)
OGH# (
Output group
No.
)
1
2
3
B/LB/B[]
/LB[]
Variable No.
Byte type
constant
4
5
A
A
Explanation
No Tag Explanation Note
1 OT# (Output No.) Specifies the number of the signal to which the pulse
signal is output.
No.: 1 to 1024
Variable B/I/D/LB/LI/
LD can be used.
2 OG# (Output group
No.)
Specifies the group number of the signal (1 group 8
points) to which the pulse signal is output.
No.: 1 to 128
Variable B/I/D/LB/LI/
LD can be used.
3 OGH# (Output group
No.)
Specifies the group number of the signal (1 group 4
points) to which the pulse signal is output.
No.: 1 to 256
Variable B/I/D/LB/LI/
LD can be used.